HKEY_LOCAL_MACHINE\Software\Cyco\AutoManager Meridian\CurrentVersion\AutocadLink

Registry values
Value Name Data Type Value Data

AcadBaseConfig

DWORD

Controls the functionality provided by the AutoCAD link:

0 – Basic AutoCAD link features only
1 – Basic AutoCAD link features plus sheet set support (default)
2 – Basic AutoCAD link features plus plain drawing asset management support (not for use with AutoCAD P&ID or AutoCAD Plant 3D)
3 – Enable all AutoCAD link features

Note    This value overrides AcadBaseConfig in HKEY_CURRENT_USER\Software\Cyco\AutoManager Meridian\CurrentVersion\AutocadLink

AcadPnIDConfig

DWORD

Controls the P&ID functionality provided by the AutoCAD link. This setting requires AutoCAD P&ID or AutoCAD Plant 3D.

0 – P&ID project features only (default)
1 – P&ID project features plus asset management support

Note    This value overrides AcadPnIDConfig in HKEY_CURRENT_USER\Software\Cyco\AutoManager Meridian\CurrentVersion\AutocadLink

Civil3DSyncWorkingFolder

DWORD

If this value is 1, synchronizes the entire folder that is specified as the working folder in AutoCAD Civil 3D. If this value is 0 (default), only the data shortcuts folder is synchronized.

Note    This value is applied of the value with the same name in HKEY_CURRENT_USER\Software\Cyco\AutoManager Meridian\CurrentVersion\AutocadLink is missing. If both values are missing, then the setting with the same name on the AutoCAD tab of the Application Link Settings in the Environment branch of the vault configuration is used.

DisableTitleBlockUpdate

DWORD

By default, the AutoCAD link updates mapped title block attributes automatically depending on the settings configured for the vault. This value provides additional control over when title block attribute updates occur.

The possible values are:

0 – Perform all automatic updates (default)
1 – Disable automatic updates when documents are opened
2 – Disable automatic updates when documents are saved
3 – Disable all automatic updates

Note    To control updates to individual title blocks, see the AutoUpdate setting described in the BlueCielo Meridian Enterprise Configuration Guide.

DocAccessSaveThumbnail

DWORD

Controls the generation of thumbnail images during link updates. If this value is 0 (default), thumbnails are not saved. If it contains 1, thumbnails are saved.

Warning    If this value is 1 and thumbnail generation fails for any reason, it could prevent property synchronization, which could be more important.

DocAccessUseTmpFileOnSave

DWORD

This setting is for supporting AutoCAD drawing title block updates over a Citrix remote access connection. If this setting is 1, the drawing is opened for reading only and changing its content is performed by using a temporary file. The default is 0.

DocAccessUseTmpFolder

DWORD

This setting is for supporting AutoCAD drawing title block updates over a Citrix remote access connection. If this setting is 1 and DocAccessUseTmpFileOnSave is set to 1, the temporary file is created in the system temporary folder. If it is set to 0 (default), the file is created in the same folder as the original file.

RealDwgFonts

String The path to RealDwg fonts installed by the Meridian Enterprise setup program.

RealDwgForceValidity

DWORD

If this value is 1 (default), the Sync Properties to File command works with AutoCAD Release 14 and older drawings but importing drawings can fail if the title blocks are synchronized also. If this value is 0, the command does not work with older drawings but importing drawings will not fail if the title blocks are synchronized.

Note    If this value is missing, then the value with the same name in HKEY_CURRENT_USER\Software\Cyco\AutoManager Meridian\CurrentVersion\AutocadLink is applied.

SyncTagsOnSave

DWORD If this value is greater than 0, updates Meridian Asset Management Module tag references when drawings are saved.

TurnOnMenuBar

DWORD

If this value is 1, shows the AutoCAD link menu bar. If this value is 0, the menu bar is hidden.

UseRowRibbon

DWORD

Controls the style of the display of the BlueCielo page in the AutoCAD Ribbon.

The possible values are:

0 – Without items rows
1 – With item rows (default)

For more information, see the BlueCielo Meridian Enterprise User's Guide .